Endeavor Resolute ZotarolimusEluting Coronary Stent System with Rapid Exchange Delivery System

  • Modelo / Serial
    Lot Numbers:  V00265135, V00265136, V00265137, V00265139, V00265140, V00265141, V00265142, V00265143, V00265144, V00265145, V00265146, V00265147, V00265148, V00265149, V00265150, V00265151, V00265152, V00265153, V00265154, V00265155, V00265156, V00265157, V00265158, V00265159, V00265160, V00265161, V00265169, V00265170, V00265171, V00265177, V00265178, V00265179, V00265180, V00265181, V00265182, V00265183, V00265188, V00265189, V00265190, V00265191, V00265194, V00265195, V00265196, V00265223, V00265224, V00265232, V00265244, V00265251, V00265254
  • Clasificación del producto
  • Clase de dispositivo
    3
  • ¿Implante?
    Yes
  • Distribución
    Nationwide distribution: AL, AR, CA, FL, IN, MD, MI, NY, OH, PA, RI, TX, VA, and VT.
  • Descripción del producto
    Endeavor Resolute Zotarolimus-Eluting Coronary Stent System with Rapid Exchange Delivery System, UPN 00613994400505, model #IDERES25024X. Manufacturer: Medtronic, Inc. Minneapolis, MN. Manufactured in: Medtronic Ireland, Galway, Ireland. Product is packaged inside a sterile, inner pouch, labeled in part "Use immediately". Inner pouch is supposed to be within a foil pouch containing desiccant, and moisture absorber. Foil pouch label reads in part "RX Endeavor Resolute Zotarolimus-Eluting Coronary Stent System...2.5 mm X 24 mm...REF IDERES25024X...Contents: One (1) Endeavor Resolute zotarolimus-eluting stent mounted on a rapid exchange stent delivery system...Guide Catheter/Minimum Inner Diameter >=5F/0.056" (1.42 mm)...Maximum Guidewire Diameter 0.014" (0.36 mm)...Maximum Stent I.D. 3.00 mm (0.12"...Nominal Pressure 9 atm (912 kPa)...Rated Burst Pressure 15 atm (1520 kPa)...MR Conditional...Sterilized using ethylene oxide Consult instructions for use...Manufacturer: Medtronic, Inc. 710 Medtronic Pkwy NE Minneapolis, MN 55432 USA...Manufactured In: Medtronic Ireland Parkmore Business Park West, Galway, Ireland Tel:+353-91-708000 Fax:+353-91-757524 Investigational Devices / Returned Goods: Tel: (800) 556-4247 / Fax: (877) 518-2469...BioLinx Medtronic Polymer System". Foil pouch contents and Instructions for Use are placed within an outer box, which is labeled identically to the foil pouch. || The Endeavor Resolute System is intended for use in patients with ischemic heart disease due to stenotic lesions contained within de novo native coronary arteries with reference vessel diameters between 2.25mm and 4.2mm and lesion lengths S 27mm that are amenable to percutaneous treatment with a stent.
  • Manufacturer
  • 1 Event

Fabricante

  • Dirección del fabricante
    Medtronic Vascular Galway Limited, Parkmore Business Park West, Galway Ireland
  • Empresa matriz del fabricante (2017)
  • Comentario del fabricante
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    USFDA