Device Recall Baxter

  • Modelo / Serial
    catalog 2C7623, lot numbers UR124917 through UR158857. Please note: Baxter lot numbers are represented by an internal reference code ''UR'' followed by a six digit sequential number, or by the letter ''U'' followed by a six digit sequential number with and ''R'' suffix. Any lot number appearing within the identified six digit sequential number range is subject to the recall.
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    No
  • Distribución
    Nationwide, Mexico, Canada, Columbia, Australia, New Zealand and Taiwan
  • Descripción del producto
    Baxter Y-Type Blood/Solution Set with Pressure Pump, 10 drops/mL, 99'', Large Standard Blood Filter, 170 to 260 Micron Filter, 2 Injection Sites, Male Luer Lock Adapter, catalog 2C7623; Baxter Healthcare Corporation, Deerfield, IL 60015 USA
  • Manufacturer
  • 1 Event

Fabricante

  • Dirección del fabricante
    Baxter Healthcare Corp., Rt 120 & Wilson Rd, Round Lake IL 60073
  • Source
    USFDA

155 dispositivos con un nombre similar

Más información acerca de la data acá

  • Modelo / Serial
    product code 2N5601, lot number UR08C31068
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    No
  • Distribución
    California and internationally to Japan and Australia
  • Descripción del producto
    Baxter Interlink System Large Bore 4-Way Stopcock, Volume 0.65 mL, Injection Site, Rotating Male Luer Lock; a sterile, nonpyrogenic fluid pathway; product code 2N5601. Intended use: For the administration of drugs and solutions to a patient's vascular system through a vascular access device.
  • Manufacturer
  • Modelo / Serial
    product code 2C7554s, lot GR293209 *** The recall was expanded to include lots GR291559 and GR294928 ***
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    No
  • Distribución
    Worldwide Distribution - USA including Alabama, Arizona, California, Illinois, Kentucky, Louisiana, New Mexico, North Carolina, Ohio, Oregon, Tennessee and Washington, and internationally to Canada and South Africa.
  • Descripción del producto
    Baxter Solution Set for Epidural Use, 110" (2.8 m), Male Luer Lock Adapter; a sterile, single use, nonpyrogenic fluid pathway for use with 6200 and 6300 series Flo-Gard Volumetric Infusion Pumps; Baxter Healthcare corporation, Deerfield, IL; product code 2C7554s || The tubing set is intended for use with Flo-Gard Infusion Pumps to provide epidural delivery of anesthetic or analgesic drugs for periods up to 96 hours.
  • Manufacturer
  • Modelo / Serial
    product code 2N3375, lot number UR09H05029, expiration date 8/25/2014.
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    No
  • Distribución
    Worldwide distribution: USA (nationwide) including: AL, LA, MO, SD, TX and WV; and country of: Canada.
  • Descripción del producto
    Baxter Interlink System Non-DEHP I.V. Catheter Extension Set, 6.6(17 cm), Volume 0.8 mL, Injection Site, Male Luer Lock Adapter; an Rx sterile, single use nonpyrogenic fluid pathway; 200 sets per case; Baxter Healthcare Corporation, Deerfield, IL 60015 USA; product code 2N3375 || Intended use: For the administration of drugs and solutions to a patient's vascular system through a vascular access device.
  • Manufacturer
  • Modelo / Serial
    Product Code 1C8507s, lot numbers GR291542, GR292409, GR292797 and GR294454.
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    No
  • Distribución
    (USA) Nationwide Distribution including the states of Alabama, California, Iowa, Illinois, Indiana, Massachusetts, Maryland, Michigan, North Carolina, New Hampshire, Ohio, Pennsylvania, Tennessee and Virginia.
  • Descripción del producto
    Baxter Solution Set with Duo-Vent Spike; 109" (2.8 m), Male Luer Lock Adapter 10 drops/mL. || Baxter Healthcare Corporation. || A sterile, single use, nonpyrogenic fluid pathway for use with rigid nonvented and flexible containers.
  • Manufacturer
  • Modelo / Serial
    product code 2M8064, serial number 8110057FB
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    No
  • Distribución
    Distributed only in Puerto Rico.
  • Descripción del producto
    Baxter Flo-Gard 6301 Dual Channel Volumetric Infusion Pump; Baxter Healthcare Corporation, Deerfield, IL 60015; Product Code # 2M8064. || The Flo-Gard Volumetric Infusion Pumps are an electromechanical pump used for intravenous infusion of fluids at user-selected rates.
  • Manufacturer
150 más