Achieva

  • Modelo / Serial
    Site numbers: 76359, 76469, 83394, 102114, 103789, 104087, 104163, 104658, 104879, 104924, 105291, 105475, 105624, 500036, 500045, 504634, 505045, 505046, 505048, 505357, 505705, 505879, 506389, 506390, 506798, 506842, 519120, 519124, 519127, 519216, 519552, 519892, 520191, 520315, 520429, 520432, 520667, 520690, 520966, 521097, 521130, 521134, 521150, 521152, 521159, 521465, 521466, 521509, 521513, 521518, 521529, 521536, 521542, 521689, 521718, 521772, 521929, 521934, 522010, 522264, 522422, 528928, 530362, 530395, 530422, 530423, 530426, 530427, 530680, 530771, 530774, 530776, 531765, 531786, 532068, 532410, 532417, 532418, 532470, 532491, 532537, 532643, 532809, 532840, 532851, 532980, 532981, 533063, 533076, 533082, 533086, 533116, 533320, 533393, 533403, 533588, 533743, 533744, 533746, 533747, 533759, 533859, 534069, 534165, 534301, 534344, 534503, 534561, 534587, 534636, 534671, 534693, 534700, 534715, 534721, 534732, 534778, 534838, 534841, 534845, 534925, 534929, 534935, 534944, 534961, 535001, 535189, 535208, 535211, 535222, 535247, 535288, 535289, 535290, 535331, 535353, 535392, 535394, 535404, 535487, 535839, 536597, 536651, 536652, 536675, 536679, 536804, 536943, 537033, 537063, 537133, 537176, 537461, 537508, 537729, 537736, 537795, 537832, 537871, 537880, 538007, 538300, 538452, 538463, 538491, 538525, 538526, 538779, 538789, 538941, 539180, 539183, 539216, 539271, 539327, 539420, 539477, 539550, 539583, 539591, 539703, 539938, 539945, 540015, 540243, 540444, 540469, 540490, 540707, 540999, 541084, 541147, 541200, 541267, 541404, 541491, 541613, 541637, 541797, 541876, 541888, 542595, 542970, 543247, 543278, 543286, 543321, 543696, 543697, 543699, 543888, 543917, 543944, 543992, 544006, 544027, 544563, 544565, 544585, 544640, 544659, 544667, 544704, 544736, 544792, 544911, 545018, 545154, 545219, 545236, 545291, 545294, 545711, 545879, 545914, 545932, 545943, 545999, 546004, 546010, 546015, 546019, 546055, 546096, 546104, 546553, 546570, 546600, 546610, 546637, 546649, 546669, 546730, 546774, 546848, 546864, 546941, 547018, 547023, 547160, 547162, 547228, 547310, 547389, 547585, 547639, 547640, 547698, 547724, 547785, 547788, 547792, 547899, 547941, 547957, 548008, 548010, 548012, 548037, 548359, 548634, 548689, 548729, 548745, 548758, 548760, 548792, 548918, 549009, 549024, 549371, 549373, 549412, 549541, 549666, 549819, 549923, 549936, 550040, 550044, 550195, 550208, 550276, 550279, 550344, 550364, 550366, 550373, 550410, 550731, 550831, 550876, 550926, 550972, 551271, 551401, 551403, 551587, 551656, 551658, 551674, 551872, 551873, 551874, 551875, 551876, 551877, 551878, 551879, 551880, 552189, 552516, 552539, 552588, 552591, 552602, 552604, 552622, 552645, 552805, 552999, 553123, 553583, 553876, 554080, 554466, 554971, 555071, 557429, 41444453, 41445275, 41616878, 42040386, 42057237, 43430017, 43720916, 43756722, 44847380, 47196007, 47598796, and 47801215.
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    No
  • Distribución
    Units were distributed throughout the US to 1,078 hospitals and medical centers.
  • Descripción del producto
    Achieva MRI
  • Manufacturer
  • 1 Event

Fabricante

  • Dirección del fabricante
    Philips Medical Systems North America Co. Phillips, 22100 Bothell Everett Hwy, Bothell WA 98021-8431
  • Source
    USFDA

62 dispositivos con un nombre similar

Más información acerca de la data acá

  • Modelo / Serial
    MR systems have a strong magnetic field around the magnet, the so called fringe field. Reduction of this fringe field (e.g. 0.5-mT area) can be required under certain circumstances. A reduction can be achieved with ferromagnetic plates mounted to the parent walls, under the construction floor and above the RF-ceiling. These plates are called passive shielding. Passive shielding calculations require dedicated Philips Healthcare software. As documented in the Planning Reference Documentation, these calculations must be performed by Philips. It provides the requirements for the thickness and the location of the shielding material which are to be implemented, preferably by Philips’ selected RF cage suppliers.
  • Descripción del producto
    MR systems
  • Manufacturer
  • Modelo / Serial
    Intera, Omniva, Enterprise, Achieva, Achieva XR, Achieva Conversion, Panorama HFO, Ingenia, SmartPath to dStream, Multiva, Prodiva, MR OR, MR-RT, MR-Linac, MR-Marlin systems
  • Descripción del producto
    MRI systems