Retiro De Equipo (Recall) de Micro Well Shuttle Weight used in VITROS 3600 Immunodiagnostic Systems and VITROS 5600 Integrated Systems

Según Department of Health, Therapeutic Goods Administration, este evento ( retiro de equipo (recall) ) involucró a un dispositivo médico en Australia que fue producido por Ortho-Clinical Diagnostics.

¿Qué es esto?

Una corrección al equipo o acción de retiro tomada por el fabricante para abordar un problema con un dispositivo médico. Los retiros (recalls) ocurren cuando un dispositivo médico está defectuoso, cuando puede poner en riesgo la salud, o cuando simultáneamente está defectuoso y puede poner en riesgo la salud.

Más información acerca de la data acá
  • Tipo de evento
    Recall
  • ID del evento
    RC-2013-RN-01249-1
  • Clase de Riesgo del Evento
    Class II
  • Fecha de inicio del evento
    2013-11-25
  • País del evento
  • Fuente del evento
    DHTGA
  • URL de la fuente del evento
  • Notas / Alertas
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Notas adicionales en la data
  • Causa
    Ortho clinical have received reports of condition codes that occurred during the calibration of microwell assays. investigations have determined that the microwell shuttle weight may be uncoated and out of manufacturing specification. if an uncoated microwell shuttle weight is installed and calibration of microwell assays is performed, there is no effect on patient samples. if an uncoated microwell shuttle weight is installed and calibration is not performed, bias results could potentially occur. internal testing has determined that quality control results using an uncoated well weight showed, on average 10% shift from established means within the quality control ranges. ortho clinical investigations has shown there is not likely to be any impact on patient safety, however, if the results are at or near a decision cut off or reference interval, this could potentially move the result into the incorrect result classification.
  • Acción
    Ortho Clinical Diagnostics (OCD) is advising users that a service technician will be inspecting all systems to identify if an uncoated MicroWell Shuttle Weight is in use and replace any affected units. If an uncoated MicroWell Shuttle Weight is identified and replaced, all MicroWell assays are required to be recalibrated. This action has been closed-out on 02/02/2016.

Device

  • Modelo / Serial
    Micro Well Shuttle Weight used in VITROS 3600 Immunodiagnostic Systems and VITROS 5600 Integrated SystemsProduct Codes: 6802783, 6802413ARTG Number: 180199An in-vitro diagnostic medical device (IVD)