Retiro De Equipo (Recall) de ThermoCool SmartTouch Catheter Family (used to facilitate electrophysiological mapping of the heart and to undertake RF ablations)

Según Department of Health, Therapeutic Goods Administration, este evento ( retiro de equipo (recall) ) involucró a un dispositivo médico en Australia que fue producido por Johnson & Johnson Medical Pty Ltd.

¿Qué es esto?

Una corrección al equipo o acción de retiro tomada por el fabricante para abordar un problema con un dispositivo médico. Los retiros (recalls) ocurren cuando un dispositivo médico está defectuoso, cuando puede poner en riesgo la salud, o cuando simultáneamente está defectuoso y puede poner en riesgo la salud.

Más información acerca de la data acá
  • Tipo de evento
    Recall
  • ID del evento
    RC-2014-RN-01156-1
  • Clase de Riesgo del Evento
    Class I
  • Fecha de inicio del evento
    2014-10-28
  • País del evento
  • Fuente del evento
    DHTGA
  • URL de la fuente del evento
  • Notas / Alertas
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Notas adicionales en la data
  • Causa
    Biosense webster, a division of johnson & johnson medical pty ltd have received complaints related to a bending/cracking at different locations of the shaft of the thermocool smarttouch catheter. none of the reported complaints were associated with any adverse events. through investigation, manual pre-shaping of the distal shaft of the catheter and use of 8 fr sheaths were identified as the two primary causes of these events. based on biosense webster's investigation, including a medical evaluation of the health risk profile from the post-market reports, biosense webster believes the overall benefit risk profile of these catheters remains in an acceptable range when used as directed in the indicated populations.
  • Acción
    Johnson & Johnson Medical Pty. Ltd (JJM) is notifying their customers of additional information included in the IFU: - Do not manually pre-shape the distal shaft of the catheter by applying external force intended to bend or affect the intended shape or curve of the catheter. - It is contraindicated to use any long sheath or short introducer < 8.5Fr in order to avoid damage to the catheter shaft. (Note: This contraindication includes Biosense Webster’s 8Fr Preface Sheath that was recommended in the initial IFU.) - Do not use excessive force to advance or withdraw the catheter if resistance is encountered during catheter manipulation through the sheath JJM is also reinforcing the procedural steps and precautions set out in the IFU - Do not use excessive force to advance or withdraw the catheter when resistance is encountered. -To verify compatibility between the sheath and catheter, advance the catheter through the sheath prior to insertion. This action has been closed-out on 15/07/2016.

Device

  • Modelo / Serial
    ThermoCool SmartTouch Catheter Family (used to facilitate electrophysiological mapping of the heart and to undertake RF ablations)Catalogue No: D132701, D132702, D132703, D132704, D132705, D133601, D133602, D133603Lot Numbers: AllARTG Numbers: 184035 & 198574
  • Clasificación del producto
  • Manufacturer

Manufacturer