Alerta De Seguridad para ADVIA CENTAUR, Registration no. 10345160020 - Serial numbers - Attachment -Carta to the Client.

Según Agência Nacional de Vigilância Sanitária (ANVISA), este evento ( alerta de seguridad ) involucró a un dispositivo médico en Brazil que fue producido por Siemens Healthcare Diagnósticos Ltda.; Siemens Healthcare Diagnostics Inc..

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • ID del evento
    1430
  • Fecha
    2014-09-26
  • País del evento
  • Fuente del evento
    ANVISA
  • URL de la fuente del evento
  • Notas / Alertas
    Brazilian data is current through June 2018. All of the data comes from Anvisa, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Brazil.
  • Notas adicionales en la data
    The company informs that patient demographics (name, age, gender, ID) of an earlier sample are incorrectly transmitted to the LIS with the current patient sample results, the data also appears incorrectly in the worklist and printed reports . Patient outcomes are not affected if the ADVIA Centaur and ADVIA Centaur XP immunoassay systems use Sample ID (SID) as the primary identifier for all outcomes. A delay in reporting may occur. The overseas manufacturer performed the problem analysis, evaluating all the inherent risks that generated the corrective action in the field. Based on the investigation and mitigation of the risk conducted, this action was classified as without health risk, its severity being low and its probability of occurrence extremely unlikely.
  • Causa
    Siemens healthcare diagnostics has identified a problem with patient demographics sent to the lis of the advia centaur® / advia centaur® xp immunoassay systems. siemens has confirmed that under extremely rare circumstances the demographics of patients from a previous order received from the lis are merged with the next order. this problem may occur when the lis data buffer becomes full in the advia centaur system, and a particular character is encountered in the last five positions in the lis data buffer.
  • Acción
    Siemens recommends following the instructions provided in the chart if the equipment in use is connected to a LIS system that transmits demographic patient data at each request. If the equipment is connected to a LIS system that does not transmit demographic patient data, no action is required. In addition, Siemens recommends retaining the letter with the laboratory records and forwarding the notification to anyone who may have access to the products.