Alerta De Seguridad para EXTERNAL DEFIBRILLATORS: LIFEPAK 1000 (Anvisa Reg. 10339190300). UNITS MANUFACTURED IN 2007.

Según Agência Nacional de Vigilância Sanitária (ANVISA), este evento ( alerta de seguridad ) involucró a un dispositivo médico en Brazil que fue producido por Physio-Control Inc.; Medtronic Comercial Ltda..

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • ID del evento
    931
  • Fecha
    2008-07-01
  • País del evento
  • Fuente del evento
    ANVISA
  • URL de la fuente del evento
  • Notas / Alertas
    Brazilian data is current through June 2018. All of the data comes from Anvisa, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Brazil.
  • Notas adicionales en la data
    According to Medtronic Commercial Ltd., the defibrillators described above were fabricated with a component that may fail due to a higher electrical leakage than normal in this item, which can cause the display to weaken and possibly the total disappearance of the data. The devices identified were manufactured in a limited number between January and December 2007 and the company said it considers it unlikely after an engineering review that the display or performance of LIFEPAK 1000 is affected by this problem. As an additional check the company is running functional tests to confirm the engineering analysis.
  • Causa
    Possibility of failure of the equipment display.
  • Acción
    Users should identify any risk-defibrillators they may have, but may continue to use them normally. It is recommended that devices be set to "auto-analyze" mode by selecting "analyze" in the device menu. If you detect that the information on the LIFEPAK 1000 defibrillator display begins to weaken or disappear completely, you must inform the product registration holder in Brazil immediately (Medtronic Comercial Ltda - Tel: (11) 2182-9200). If the display erases during use, the recommended measures are as follows: (1) Continue to use LIFEPAK 1000 to treat the patient (voice and sound messages work normally); (2) If the equipment is not set to "auto-analyze," use the right-hand key at the bottom of the screen to select Analyze.

Manufacturer