Retiro De Equipo (Recall) de ECLIPSE TPS V8.8

Según Health Canada (via FOI), este evento ( retiro de equipo (recall) ) involucró a un dispositivo médico en Canada que fue producido por VARIAN MEDICAL SYSTEMS INC..

¿Qué es esto?

Una corrección al equipo o acción de retiro tomada por el fabricante para abordar un problema con un dispositivo médico. Los retiros (recalls) ocurren cuando un dispositivo médico está defectuoso, cuando puede poner en riesgo la salud, o cuando simultáneamente está defectuoso y puede poner en riesgo la salud.

Más información acerca de la data acá
  • Tipo de evento
    Recall
  • ID del evento
    90044
  • Clase de Riesgo del Evento
    II
  • Fecha de inicio del evento
    2012-05-16
  • País del evento
  • Fuente del evento
    HC
  • Notas / Alertas
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • Notas adicionales en la data
  • Causa
    An anomaly identified with the eclipse treatment planning system where the calculated dose distribution is not updated or invalidated when a recalculation or reload is performed while the compensator or fluence editor is open. this may go unnoticed. proceeding to approve and treat with such a plan can result in the delivered dose distribution not matching the calculated dose distribution. if a dose calculation or plan reload is performed while the compensator or fluence editor dialog is open the resultant dose distribution will be based on the compensator applied prior to edit. when the dialog box is subsequently closed the compensator will be updated. however the calculated dose distribution will not reflect the new compensator. use of the compensator for treatment will result in a dose different from the planned dose. if a verification plan is generated it will be based on the updated compensator such that the error is likely to go undetected.

Device

  • Modelo / Serial
    Model Catalog: 100042024 (Lot serial: Contact manufacturer.); Model Catalog: TPA001075000 (Lot serial: H482173); Model Catalog: 100042024 (Lot serial: >10 serial numbers.); Model Catalog: TPA001075000 (Lot serial: H481730); Model Catalog: UP9001 (Lot serial: Contact manufacturer.); Model Catalog: UP9001 (Lot serial: >10 serial numbers.)
  • Descripción del producto
    ECLIPSE Treatment Planning System V8.8