Alerta De Seguridad para 4d integrated treatment console versions 8.1.3 to 8.8

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por Varian Medical Systems.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2012-04-18
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Field safety notice: 4d integrated treatment console (4ditc) versions 8.1.3 to 8.8 medical device manufacturer, varian medical systems, has issued an urgent field safety notice concerning 4d integrated treatment console (4ditc) v8.1.3 to 8.8. varian has identified that after a plan with wedge field has been opened in 4d integrated treatment console, users may not notice that the wedge filter may actually be missing from a selected field, and the treatment application will not notify the user of this anomaly and will not prevent beam delivery. the user may come to understand that the wedge filter is missing only after the treatment field has been partially or completely delivered and when the user attempts to close the patient from the treatment application. with this situation the treatment application forces the user to unload the patient, requires user authorization, and informs the user that the treatment record for the missing wedge field will not be saved to the ois. varian supplemented that delivery of a treatment field without the planned and calculated wedge filter could result in an over dosage for that beam and potentially an unintended dose uniformity of the target treatment volume. varian is now notifying all affected customers and providing instructions regarding the use of wedges and secondary channel integrity check (scic) which is a data integrity check to further ensure safety of the radiation beam delivery. in addition, varian will provide a software upgrade to all affected users to correct the problems mentioned above. according to the local supplier, the affected devices have been distributed in hong kong. if you are in possession of the affected product, please contact your supplier for necessary actions.

Device

  • Modelo / Serial
  • Descripción del producto
    Medical Device Safety Alert: 4D Integrated Treatment Console (4DITC) versions 8.1.3 to 8.8