Alerta De Seguridad para Acetaminophen L3K Assay

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por Sekisui Diagnostics.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2016-01-29
  • Fecha de publicación del evento
    2016-01-29
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Medical device safety alert: sekisui diagnostics acetaminophen l3k assay medical device manufacturer, sekisui diagnostics, has issued a medical device safety alert concerning its acetaminophen l3k assay [list number: 506-10 (lot numbers: 47677, 47694, 47649, 47650, 47662, 47663, 48253, 48385, 48386) and 506-30 (lot numbers: 47695, 48294)] abbott diagnostics has received a field safety notice (fsn) from sekisui, the manufacturer of acetaminophen reagent. according to the fsn, sekisui has investigated complaints related to the formation of crystals in the r2 reagent and/or shift of controls when left on board an automated analyzer. during the investigation, it was determined that when the r2 reagent is exposed to the atmosphere for prolonged periods of time, on board an automated analyzer, crystals may form. sekisui has identified the crystals form a standard component of the reagent. the amount of time to crystalise is dependent on reagent usage, temperature, and length of time on board the analyzer. abbott internal testing has shown that the crystal formation does not impact architect csystem instrument performance. sekisui has made the decision to reduce the expiration date of the acetaminophen l3k reagent, catalogue number 506-10 and 506-30, to 9 months from 18 months due to the findings during the investigation. to date, no impact to patient results has been identified. a review of previously reported patient results is not required, however, if affected users chose to do so, they are instructed to follow their standard laboratory protocol. affected users are advised to take the following actions:- discard all reagent in house with a current expiration date of 2016-09. update the expiration on all remaining kits on hand with the expiration dates provided by the manufacturer. reagent requires a daily (24 hour) calibration. reagent should remain on the abbot architect analyzer for a maximum of 8 days. use a minimum volume of 20ml of r2 reagent at a time, using only 20ml wedges. when adding additional reagent to the analyzer use a new wedge. if crystals are observed within reagent stored on-board, reagent should be discarded and replaced with fresh reagent. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 29 january 2016.

Device

  • Modelo / Serial
  • Descripción del producto
    Medical Device Safety Alert: Sekisui Diagnostics Acetaminophen L3K Assay
  • Manufacturer

Manufacturer