Alerta De Seguridad para Advantx, Innova 2000, Innova 2100IQ, Innova 3100, Innova 3100IQ, Innova 4100, Innova 4100IQ Cardiovascular X-ray imaging systems

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por GE Healthcare.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2013-09-10
  • Fecha de publicación del evento
    2013-09-10
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Medical device safety alert: ge advantx, innova 2000, innova 2100iq, innova 3100, innova 3100iq, innova 4100, innova 4100iq cardiovascular x-ray imaging systems the medicines and healthcare products regulatory agency (mhra), united kingdom (uk) posted a medical device safety alert concerning all advantx, innova 2000, innova 2100iq, innova 3100, innova 3100iq, innova 4100, innova 4100iq cardiovascular x-ray imaging systems equipped with video monitor suspension manufactured by ge healthcare. systems equipped with lcd or large display monitor suspensions are not affected. it has been identified during several preventive maintenance activities that the 4 outer screws that hold the overhead video monitor suspension to the carriage were found missing since installation of the system. there is a potential that the system has not been installed per specified installation requirements. the manufacturer is not aware of any fall of the overhead monitor suspension. however, missing screws may increase the risk for fall of the monitor suspension. no injury has been reported due to this issue. the manufacturer will inspect all potentially affected systems to verify that the overhead video monitor suspensions are properly installed and will correct all affected systems. for details, please visit the following mhra website: http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/con309649 if you are in possession of the product, please contact your supplier for necessary actions. posted on 10 september 2013.

Device

  • Modelo / Serial
  • Descripción del producto
    Medical Device Safety Alert: GE Advantx, Innova 2000, Innova 2100IQ, Innova 3100, Innova 3100IQ, Innova 4100, Innova 4100IQ Cardiovascular X-ray imaging systems
  • Manufacturer

Manufacturer