Alerta De Seguridad para Denali Inferior Vena Cava (IVC) Filter

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por Bard Peripheral Vascular.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2016-02-18
  • Fecha de publicación del evento
    2016-02-18
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Medical device safety alert: bard denali inferior vena cava (ivc) filter medical device manufacturer, bard peripheral vascular, inc. (bpv), has issued a medical device safety alert concerning its denali ivc filter. specific product code/lot number combinations of denali ivc filter are affected and the affected code numbers are as follows: dl900j: denali filter - jugular/subclavian delivery system dl900f: denali filter - femoral delivery system dl950j: denali fitter - jugular/subclavian delivery system dl950f: denali filter - femoral delivery system on 18 december 2015, nordson medical, notified bpv of an issue with the stop cock that is included in the denali ivc filter introducer set. according to nordson medical, specific lots of stop cocks are at risk of having cracks in the stop cock body. according to bpv, all assemblies including the stop cock, are 100% tested to ensure no leaks are present in the assembled device during the manufacturing process. furthermore, bpv recently conducted simulated clinical use testing utilising product with visible cracks on the stop cock. all testing passed the criteria of not leaking. as such, bpv concluded that the cracking is superficial in nature with no impact on product performance or patient safely. a clinical health hazard was performed by bpv considering all potential clinical issues that could arise from a crack in the indicated location. this assessment concluded that, in the worst case, if an unsuspecting user utilised a denali ivc filter with a cracked stop cock, it is possible that a drop of fluid could form on the stop cock during flushing of the introducer or during the negative pressure associated with aspiration a small amount of air could be drawn into the syringe. in both cases, it is unlikely that the leak would be noticed by the user. bpv is removing the affected products from the customers impacted by the nordson recall. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 18 february 2016.

Device

  • Modelo / Serial
  • Descripción del producto
    Medical Device Safety Alert: Bard Denali Inferior Vena Cava (IVC) Filter
  • Manufacturer

Manufacturer