Alerta De Seguridad para Hexagonal Socket, Ø 4.0mm/11.0mm

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por Synthes GmbH.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2015-08-07
  • Fecha de publicación del evento
    2015-08-07
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Medical device safety alert: synthes gmbh hexagonal socket, ø 4.0mm/11.0mm medical device manufacturer, synthes gmbh, has issued a medical device safety alert concerning its hexagonal socket, ø 4.0mm/11.0mm [part number: 356.714; lot number: all]. the manufacturer is initiating a voluntary medical device recall of the above mentioned part and lot numbers of the depuy synthes hexagonal socket, ø 4.0mm/11.0mm. the socket is a cannulated instrument used to insert the end caps in the following nail systems: proximal femoral nail anti-rotation (pfna), pfna-ii, and the antegrade femoral nail (afn). there is a potential for the socket-hex tip to break into fragments during use if too much force is applied. breakage of the hex tip may result in surgical delay and an adverse tissue reaction. as the affected item has been reported to break intra-operatively, there is potential for surgical delay while the fragments are retrieved. consequently, surgical delay may occur while a replacement instrument or alternative device is located to insert the end cap. in addition, an adverse tissue reaction may possibly occur if any stainless steel fragments from the socket are not retrieved from the patient. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 07 august 2015.

Device

  • Modelo / Serial
  • Descripción del producto
    Medical Device Safety Alert: Synthes GmbH Hexagonal Socket, Ø 4.0mm/11.0mm
  • Manufacturer

Manufacturer