Alerta De Seguridad para HomeChoice Automated Peritoneal Dialysis system, 230V

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por Baxter Healthcare.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2013-10-21
  • Fecha de publicación del evento
    2013-10-21
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Medical device safety alert: baxter homechoice automated peritoneal dialysis system, 230v medical device manufacturer, baxter healthcare, has issued a field safety notice concerning homechoice automated peritoneal dialysis system, 230v (product code: 5c4474; software version: v10.4). baxter is sending a communication to describe homechoice 10.4 software initial drin logic in patients with unrelated co-morbid condition of ascites. ascites is the abnormal accumulation of fluid in the peritoneal cavity. peritoneal dialysis patients with ascites may have large volumes of fluid in their peritoneal cavity. when these patients drain significant amounts of ascetic fluid (e.G. more than 5 liters), studies suggest that medical intervention may be required to mitigate against developing hypotension and potential hemodynamic compromise. homechoice software is designed to empty the peritoneal cavity during initial drain. previous versions of homechoice software permitted the operator to stop the active initial drain and bypass it. the current version of the homechoice software version 10.4 removed the option to bypass an active initial drain in order to mitigate against unintended increased intraperitoneal volume. patients diagnosed with the co-morid condition of ascites who drain to empty may be at an increase risk of hypotension and compromise of their hemodynamic status. therefore, baxter advises that clinicians using the homechoice to treat patients diagnosed with end stage renal disease coincident with ascites should: be aware that homechoice will attempt to drain the patient to empty at the beginning of therapy (initial drain) review homechoice ifu for additional details on homechoice 10.4 initial drain logic. according to the local supplier, the affected products were distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 21 october 2013.

Device

  • Modelo / Serial
  • Descripción del producto
    Medical Device Safety Alert: Baxter HomeChoice Automated Peritoneal Dialysis system, 230V
  • Manufacturer

Manufacturer