Alerta De Seguridad para NOxBOXi inhaled Nitric Oxide Delivery and Monitoring Device

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por Bedfont Scientific.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2014-05-07
  • Fecha de publicación del evento
    2014-05-07
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Medical device safety alert: bedfont scientific noxboxi inhaled nitric oxide delivery and monitoring device the medicines and healthcare products regulatory agency (mhra), united kingdom posted a field safety notice concerning noxboxi inhaled nitric oxide delivery and monitoring device, manufactured by bedfont scientific. a conflict has been identified between the noxboxi regulators output and the cylinder status symbols shown on-screen. due to tolerances on the regulator output, some units may show a cylinder status as empty (red) when in fact they are full and some may show as full (green) when they are empty. with the latter a cylinder could empty without the operators knowledge, the system will switch over to the auxiliary/back-up cylinder, however when that is exhausted and system would then alarm “supply critical”. if another supply of gas is not available, sudden cessation of the therapy could occur. for patients dependent on this therapy, this failure could result in serious injury or death of the patient. the manufacturer advises affected users not to use the cylinder status icons on screen to determine gas supply. furthermore, the manufacturer is evaluating a firmware fix whereby the cylinder status tolerances are widened in order to eradicate the risk of cylinders showing as empty when they are full and full when they are empty. the regulators have a gas pressure gauge built into them which shows the cylinder status and this must be used only until a firmware fix is validated. for details, please refer to the following link:http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/con409264 if you are in possession of the affected product, please contact your supplier for necessary actions. posted on 07 may 2014.

Device

  • Modelo / Serial
  • Descripción del producto
    Medical Device Safety Alert: Bedfont Scientific NOxBOXi inhaled Nitric Oxide Delivery and Monitoring Device
  • Manufacturer

Manufacturer