Alerta De Seguridad para Precise Digital Accelerator, Synergy Platform, Synergy, Synergy S, Infinity, Axesse (Various Models, All lot no.)

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por Elekta Limited.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2011-12-14
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Field safety notice: elekta precise digital accelerator, synergy platform, synergy, synergy s, infinity, axesse (various models, all lot no.) medical device manufacturer, elekta limited, has issued a field safety notice on precise digital accelerator, synergy platform, synergy, synergy s, infinity, axesse, linear accelerator systems. a small number of reverse modulator diodes, a component in the equipment room of the linear accelerator, have ruptured. customers have heard a loud explosion in the equipment room sometime after beam termination. the patient and clinical operators are not at risk. a service engineer, or any personnel entering the equipment room could sustain serious injury. elekta reported that no incidents involving personnel have occurred. elekta has communicated with the users about the fitting of a reverse diode cover and advised that personnel who enter the equipment room should wear protective safety glasses before the cover is fitted. according to the local supplier, the affected devices have been distributed in hong kong. if you are in possession of the affected product, please contact your supplier.

Device

  • Modelo / Serial
  • Descripción del producto
    Medical Device Safety Alert: Elekta Precise Digital Accelerator, Synergy Platform, Synergy, Synergy S, Infinity, Axesse (Various Models, All lot no.)
  • Manufacturer

Manufacturer

  • Empresa matriz del fabricante (2017)
  • Source
    DH