Alerta De Seguridad para Spectra Optia Apheresis System

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por Terumo BCT.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2013-08-23
  • Fecha de publicación del evento
    2013-08-23
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Medical device safety alert: terumo bct spectra optia apheresis system medical device manufacturer, terumo bct, inc., has issued a field safety notice concerning spectra optia apheresis system. terumo bct has modified the spectra optia system’s standard filler in order to reduce the incidence of leaks in the channel of the tubing set during mononuclear cell (mnc) collection procedures. leaks in the channel of the tubing set have many different causes. the manufacturer has identified a very specific type of channel leak caused by a pinhole-sized tear in the soft vinyl wall near the set’s hard plastic connector. this type of leak has occurred primarily during long mnc collection procedures and results in a minor blood spill that remains fully contained within the system’s centrifuge chamber. although the reported incidence of this type of channel leak is quite low (< 0.23% in spectra optia collection sets manufactured since july, 2010) and no serious adverse events have been reported, even a small tubing set leak can result in the premature termination of an apheresis procedure. consequently, terumo bct has modified and strengthened the system’s standard filler to better support the tubing set during centrifugation. according to the manufacturer, to help identify the modified filler, “spectra optia” is engraved on the top side of the filler. terumo bct will provide one modified standard filler for each device to all customers who use the system to perform mnc collection procedures. the manufacturer will begin installing the modified filler over a 12-month period, with the installation likely occurring during a scheduled preventive maintenance visit. the machine’s original filler will be removed from facility for recycling/disposal. according to the local supplier, the affected products were distributed in hong kong. if you are in possession of the products, please contact your supplier for necessary actions. posted on 23 august 2013.

Device

  • Modelo / Serial
  • Descripción del producto
    Medical Device Safety Alert: Terumo BCT Spectra Optia Apheresis Systems