Alerta De Seguridad para Standard Offset Cup Impactor

Según Department of Health, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Hong Kong que fue producido por Greatbatch Medical.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Fecha
    2014-03-13
  • Fecha de publicación del evento
    2014-03-13
  • País del evento
  • Fuente del evento
    DH
  • URL de la fuente del evento
  • Notas / Alertas
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Notas adicionales en la data
    Medical Device Safety Alert
  • Causa
    Medical device safety alert: greatbatch medical standard offset cup impactor the united states food and drug administration (fda) has issued a medical device safety alert concerning standard offset cup impactor manufactured by greatbatch medical. the affected device was manufactured from january 2004 through january 2013 and distributed from january 2004 through december 2013. the manufacturer has identified through internal sterility assurance level validation testing that a sterility assurance level of 10-6 is not achieved on the standard offset cup impactor when it is subjected to the steam sterilization cycles and associated dry times that are specified in the current instructions for use provided with the device. the manufacturer has not received any reports of deaths, illnesses, injuries, or other adverse effects associated with this issue. greatbatch has developed new sterilization recommendations that meet acceptable sterility assurance levels (aami st79 standard). customers who have the affected product should immediately begin utilizing the new sterilization instructions. for details, please refer to the following fda websites: http://www.Accessdata.Fda.Gov/scripts/enforcement/enforce_rpt-product-tabs.Cfm?action=select&recall_number=z-1119-2014&w=03122014&lang=eng http://www.Fda.Gov/safety/medwatch/safetyinformation/safetyalertsforhumanmedicalproducts/ucm388928.Htm http://www.Fda.Gov/medicaldevices/safety/listofrecalls/ucm389005.Htm http://www.Fda.Gov/safety/recalls/ucm388883.Htm if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 13 march 2014.

Device

  • Modelo / Serial
  • Clasificación del producto
  • Descripción del producto
    Medical Device Safety Alert: Greatbatch Medical Standard Offset Cup Impactor