Alerta De Seguridad para BD Vacutainer® Plus SST Tube with Hemogard Closure

Según Food and Drug Administration Philippines, este evento ( alerta de seguridad ) involucró a un dispositivo médico en Philippines que fue producido por BD.

¿Qué es esto?

Las alertas proporcionan información importante y recomendaciones sobre los productos. Aunque se haya emitido una alerta, esto no significa necesariamente que el producto se considera peligroso. Las alertas de seguridad, dirigidas a trabajadores de la salud y a usuarios, pueden incluir retiro de equipos. Pueden ser escritas por los fabricantes, pero también por funcionarios del área de salud.

Más información acerca de la data acá
  • Tipo de evento
    Safety alert
  • Número del evento
    2018-160
  • País del evento
  • Fuente del evento
    FDAP
  • URL de la fuente del evento
  • Notas / Alertas
    Data from the Philippines is current through 2019. All of the data comes from the Food and Drug Administration Philippines, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Philippines.
  • Notas adicionales en la data
  • Causa
    Fda advisory no. 2018-160  voluntary recall of the bd vacutainer® plus sst tube with hemogard closure with product registration dvr no. 3713 metro drug inc., the importer/distributor of bd vacutainer® plus sst tube with hemogard closure with the product registration number dvr-3713. has informed the food and drug administration of the voluntary recall of the said product, specifically described as follows: product name bd vacutainer® plus sst tube with hemogard closure specifications 13x75mm x 3.5ml catalog code 367983 lot no. 7135828 and 7125692 intended use for the collection of venous blood packaging/selling unit shelf pack of 100 tubes/case of 10 shelf packs registration no. dvr-3713 product name bd vacutainer® plus sst tube with hemogard closure specification 13x100mm 5.0ml catalog no. 367986 lot no. 7146901 intended use for the collection of venous blood packaging/selling shelf pack of 100 tubes/case of 10 shelf packs registration no. dvr-3713 said items are being voluntarily recalled due to reports of bd has confirmed that a limited number of tubes associated with the above lots of bd portion of the lots bd vacutainer® plus sst tubes which are currently in the market may exhibit stopper creeper-out/pull-out/pop-off, where the stopper dissociates from the tube. an example of stopper creep-out/pull-out/pop-off is demonstrated in figure above. bd has received reports of this issue occurring during collection and processing (including centrifugation, transportation and testing). stopper creep-out/pull-out/ pop –off can result in potential user exposure to blood resulting from an un- stoppered tube, which may result in exposure to blood borne pathogens. lot and ref numbers that are critical in determining the identity of the product for traceability. in the report to the fda , metro drug inc. disclosed that the affected lots were not distributed in the philippine market as per their distribution list record. at any rate, distributors, retailers and hospitals that have any lot of the stated medical device product are instructed to discontinue their further distribution, sale, and use. furthermore, other distributors of said product shall coordinate with the fda for the conduct of product recall. all consumers are likewise advised not to purchase or use the affected product lots. any suspected adverse reaction experienced or any incident of the same cases from the use of the device but not limited to the lots stated above, should be reported immediately to fda at telephone no. (02) 857-1900 loc. 8301 or email us at this email address is being protected from spambots. you need javascript enabled to view it. . dissemination of the information to all concerned is requested. attachments: fda advisory no. 2018-160.Pdf.

Device

Manufacturer

BD