  • Dispositivo 128
  • Fabricante 31827
  • Evento 155
  • Implante 27
HiRes 90K
  • Modelo / Serial
    Serial Numbers:  351323, 251153, 350989, 351226, 350196, 351136, 350140, 350201, 351261, 351264, 351266, 351269, 351412, 351415, 351429, 350157, 351303.
  • Clasificación del producto
    Ear, Nose, and Throat Devices
  • Clase de dispositivo
    3
  • ¿Implante?
    Yes
  • Distribución
    Worldwide distribution: USA (nationwide) including state: IL and country of: Europe.
  • Descripción del producto
    HiRes 90K devices with Helix Electrodes Model CI 1400-02H || The HiResolution Bionic Ear System is a cochlear implant system designed to provide useful hearing to individuals with severe to profound hearing loss. It consists of internal and external components. The internal components include a stimulator (HiRes90K ICS) and electrode array (HiFocus 1j or Helix). The HiRes90K ICS is implanted surgically under the skin behind the ear. The electrode array is inserted into the cochlea. The external components include a sound processor (body-worn or ear-level), a headpiece, and a cable. The system converts sound into electrical energy that activates the auditory nerve. The auditory nerve then sends information to the brain, where it is interpreted as sound. The Helix consists of a fantail, electrode lead, and Helix electrode array. The electrode, comprised of platinum-iridium wires, is housed in a silicone carrier and extends from the titanium case. The Helix electrode array is 24.5 mm in length and is designed to be inserted approximately 18-21 mm into a normal patent cochlea. It consists of 16 planar contacts arranged along the medial surface of the electrode array for stimulation of discrete segments of the cochlea. The Helix electrode insertion tool is designed to assist the surgeon with the insertion of the Helix electrode. Only the Helix insertion should be used for insertion of the Helix electrode; the use of other instruments may result in damage to the electrode. The insertion tool is a single-use instrument.
  • Manufacturer
    Advanced Bionics Corporation
  • 1 Event
    • Retiro De Equipo (Recall) de HiRes 90K
Device Recall SP78100, SP78105 Nasal Septal Button Standard (3cm)
  • Modelo / Serial
    Model / Lot #: SP78100 / 114149, SP78105 / 114219.
  • Clasificación del producto
    Ear, Nose, and Throat Devices
  • Clase de dispositivo
    Unclassified
  • ¿Implante?
    Yes
  • Distribución
    Nationwide Distribution in the states of CA, CT, DE, FL, GA, ID, IL, IN, MD, MA, MI, MN, NJ, NY, NC, PA, TX, UT, and WI. FRANCE, NETHERLANDS, BELGIUM, UNITED KINGDOM, CANADA, ISRAEL, PERU, SPAIN, IRELAND.
  • Descripción del producto
    SP78100, SP78105 || Nasal Products, Catalog Number SP-78100, Nasal Septal Button Standard (3cm), Rx Only, Sterilized by Ethylene Oxide, Micromedics Inc., St Paul, MN 55121-1385. || Nasal Products, Catalog Number SP-78105, Nasal Septal Button Oversize (5cm), Rx Only, Sterilized by Ethylene Oxide, Micromedics Inc., St Paul, MN 55121-1385.
  • Manufacturer
    Micromedics, Inc.
  • 1 Event
    • Retiro De Equipo (Recall) de Device Recall SP78100, SP78105 Nasal Septal Button Standard (3cm)
  • « First
  • ‹ Prev
  • 1
  • 2

Acerca de la base de datos

Explore más de 120,000 registros de retiros, alertas y notificaciones de seguridad de dispositivos médicos y sus conexiones con los fabricantes.

  • Preguntas frecuentes
  • Acerca de la base de datos
  • Contáctenos
  • Créditos

Historias en su correo

¿Trabaja en la industria médica? ¿O tiene experiencia con algún dispositivo médico? Nuestra reportería no ha terminado. Queremos oír de usted.

¡Cuéntanos tu historia!

Aviso

Los dispositivos médicos ayudan con el diagnóstico, la prevención y el tratamiento de muchas lesiones y enfermedades. A través de la International Medical Devices Database no estamos sugiriendo que compañías u otras entidades mencionadas en la base de datos hayan sido parte de una conducta ilegal o hayan actuado de manera impropia. Un mismo dispositivo médico puede tener distintos nombres en diferentes países. Esta base de datos no busca proporcionar asesoría médica. Los pacientes deben consultar con sus médicos para determinar si la data contiene información relevante y si la misma tiene implicaciones médicas para ellos.