Causa
The system 6 aseptic battery kit provides a sterile enclosure for the styker non-sterile battery. the manufacturer has identified the affected lot to have insufficient bond strength at a weld joint associated with the aseptic housing, due to an issue during manufacture. therefore, the quality of the weld may not be as effective as intended. this could lead to the separation of the top section of the housing from the bottom section. this may lead to sterility breaches, loss of surgical control, intra-operative complications and potential delays in surgery.
Acción
Affected units will be replaced via the standard stock replenishment process. This action has been closed-out on 18/08/2016.
Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
Notas adicionales en la data
Causa
Zimmer biomet is conducting a lot specific medical device recall for various polyethylene implants. the affected products are being removed due to the potential presence of elevated endotoxin levels that exceed the specification limit. the issue was discovered during routine bacterial endotoxin testing (bet). to date, no complaints related to this issue have been received.
Acción
The relevant Zimmer Biomet sales representative will remove the affected product from each affected facility. There are no specific patient monitoring instructions that are recommended beyond the existing surgical follow-up protocol.
Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
Notas adicionales en la data
Causa
Medtronic has become aware of instances where spine clamps have been damaged when forced open beyond their intended limits during use and will subsequently not open once attached to a patient’s spinous process. when the spine clamp is forced open beyond its intended limits, a component (captive washer) may break off. the washer could then be inadvertently left behind in a patient’s body if the breakage occurs during the procedure. if the washer is missing from the device, the spine clamp cannot be re-opened after placement on the spinous process.Medtronic has received six reports where unintended removal of spinous process occurred when attempting to detach the spine clamp. the unintended removal of spinous process can lead to damage of adjacent vertebra and cause premature degradation.
Acción
Medtronic is providing an interim workaround for users via the Customer Letter. A new version of the clamps with a design mitigation will be distributed as a permanent correction once available.
Lebanese data is current through July 2018. All of the data comes from the Ministry of Public Health (Republic of Lebanon), except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Lebanon.
Lebanese data is current through July 2018. All of the data comes from the Ministry of Public Health (Republic of Lebanon), except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Lebanon.
Lebanese data is current through July 2018. All of the data comes from the Ministry of Public Health (Republic of Lebanon), except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Lebanon.
Lebanese data is current through July 2018. All of the data comes from the Ministry of Public Health (Republic of Lebanon), except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Lebanon.
Lebanese data is current through July 2018. All of the data comes from the Ministry of Public Health (Republic of Lebanon), except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Lebanon.
Lebanese data is current through July 2018. All of the data comes from the Ministry of Public Health (Republic of Lebanon), except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Lebanon.
Danish data is current through March 2019. All of the data comes from the Danish Medicines Agency, except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Denmark.