Worldwide Distribution - USA including DC, IN, FL, HI, LA, NY, MD, MI, OH,OR, WI, WY, Foreign: Great Britain, Italy, and France
Descripción del producto
Integra InterFix CT Adapter (CTA) || Intended for cranial fixation during CT scanning and || treatment with the TomoTherapy HiArt (Torno) System || The Integra InterFix CT Adapter (CTA) kits are intended for cranial fixation during CT and and treatment with the Tomo Therapy Hi-Art system. Provides adapters for attaching: Integra head rings to the following: 1.Flat CT scanner tabletops ranging form 47cm to 54 cm 2. TomoTherapy Hi-Art system tabletop
Distributed in the states of IL, ID, LA, MA, NJ, NY, OH, PA, and SD.
Descripción del producto
Integra XKnife¿ Stereotactic Radiosurgery and Radiotherapy Treatment Planning, || Software Versions 5.0.1 and 5.0.2. || Intended for use in stereotactic and non-stereotactic (frameless stereotactic), collimated beam, computer planned, linear accelerator (Linac) based treatment.
Nationwide Distribution to OK, CA, TX, WA, GA, NY, MS, NY, PA
Descripción del producto
K-wire, Smooth Double-pointed 0.8 x 90mm, a component of the METASURG Capture Screw System || The K-wire is used in conjunction with the 2.0 mm cannulated screws for the METASURG Capture Screw System. The K-wire is used by the physician to insert into the bone and to act as a guide for drilling, countersinking and installing screws
Worldwide Distribution - USA (nationwide) including the states of; AL, AR, AZ, CA, CO, CT, DE, FL, GA, IA, ID, IL, IN, KY, MA, MD, MI, MO, MN, NC, NJ, NM, NV, NY, OH, OK, OR, PA, RI, TN, TX, UT, VA, WA & WI. Product was also shipped to the following countries: Austria, Belgium, Canada, Czech Republic, France, Germany, Ireland, Israel, Italy, Lebanon, Saudi Arabia, South Africa, Spain, Sweden, Switzerland & United Kingdom.
Descripción del producto
Tibiaxys¿ Ankle Arthrodesis Plate Compression Guide, Model #159635, part # 159 635, Batch #: EAHZ, EAJ1, ELGV, ENQE & ENQH. || Product Usage: || The Compression guide is a re-usable instrument used in the implantation of the Tibiaxys product. The Tibiaxys system is intended for fixation of bone fractures or for bone reconstruction (arthrodesis, osteotomies, and fractures of ankle joint, distal tibia and fibula).
Nationwide Distribution, including the states of: MI, CA, TX, VT, OK, OH, NC, MN, CT, CO, TN, NY, NJ, MO, FL, WA, AR, MT, VA, IL, PA, NE, GA, AZ, WI, OR, MD, LA, IA, AL, MA, ID, KY, UT, NV, IN and SC.
Descripción del producto
Integra Endoscopic Gastrocnemius Release (EGR) System. The device consists of one (1) unit which is kitted within an instrumentation tray. The Integra EGR System includes a range of instruments for endoscopic approach to the Gastrocnemius Aponeurosis Recession. The cutting instrument features a retracting blade for cutting the gastrocnemius aponeurosis. Associated instruments include an elevator, a cannula, and a cannula obturator, which are all consumable instruments provided sterile. The EGR System is indicated for the treatment of posterior heel cord contracture (Equinus) in those patients who fail to respond to conservative management.
Worldwide Distribution - US Nationwide and the countries of Canada, Australia, Arab Emirates, Denmark, Germany, Great Britain, India, Ireland, Israel, Japan, Kuwait, Lebanon, Malta., Netherlands, Panama, Poland, Saudi Arabia, Singapore, South Africa, Spain, Sweden, and Tunisia.
Descripción del producto
Integra¿ LED Battery Charger, Single Bay. || Product Number: 90523 || The LED Headlight System Battery Charger (90523) is an accessory to the LED Headlight System: || 90520US - LED Headlight w/Battery & AC/DC Power Supply - US || 90520EU - LED Headlight w/Battery & AC/DC Power Supply - EU || 90520UK - LED Headlight w/Battery & AC/DC Power Supply - UK || 90520AU - LED Headlight w/Battery & AC/DC Power Supply - AU || Product Usage: The Integra LED Headlight System Is designed to provide illumination to aid visualization during minor surgical, diagnostic, or therapeutic procedures
Worldwide Distribution - USA Nationwide including Canada.
Descripción del producto
Integra(R) Jarit(R) Monopolar Cable (Catalogue No. 600-290). || For use in endoscopic surgery. For use when a rigid endoscopic instrument for grasping and/or dissecting if soft tissue is determined to be appropriate by the surgeon. Monopolar electrosurgical current can be used for coagulation and/or cutting.
1104HC Integra NeuroSciences Ventricular Bold Monitoring Kit W/ Cranial Access, Drain including (1) Cranial Kit W/Cam. Chuck, (1) Ventricular Bolt ICP Monitoring Kit, (1) CSF Drainage System. Contains Sterile and Non-Sterile Product. Integra Life Sciences 3498 West 2400 South, West Valley City, Utah 84119. || Product Usage: The Xylocaine component of the kit is used as an injectable local anesthetic during cranial access operations.
Worldwide Distribution - US (Nationwide) and Internationally to ARGENTINA, BRAZIL, BULGARIA, CANADA, COLUMBIA, COSTA RICA, FRANCE, GERMANY, ITALY, MEXICO, GERMANY, ITALY, MEXICO, PANAMA, SOUTH AFRICA, SPAIN, SWITZERLAND, UNITED ARAB EMIRATES, AND UNITED KINGDOM
Descripción del producto
Integra Camino Intracranial Pressure Monitoring Catheter with Licox IMC Bolt Fitting, Catalog No. 110-4L || The Camino Intracranial Pressure Monitoring Catheter is a sterile transducer-tipped pressure monitoring catheter with accessory items to be used as a diagnostic tool for rapidly determining and continuously monitoring intracranial pressure. The Camino catheter has a miniature transducer at the distal tip. This design eliminates the need for a fluid-filled system to carry pressure waves to an external transducer and thus, the problems inherent in such fluid-filled systems are eliminated. The Camino catheter is packaged with a zero adjustment tool which allows for the adjustment of the transducer during catheter preparation, and the LICOX Bolt Adapter Fitting. The Camino Intracranial Pressure Monitoring Catheter with Licox IMC Bolt fitting, Model 110-4L is indicated for use by a qualified Neurosurgeon when direct measurement of intracranial pressure in the parenchyma is clinically important. It is intended to be used only through a Licox Brain Oxygen Monitoring System Bolt.
Worldwide Distribution - US Distribution to the states of : NJ, TX and WY., and to the countries of : Algeria, Germany and India.
Descripción del producto
Universal Compact Head Ring Adapter Plate (UCHRAP), a component of the Universal Compact Head Ring Adapter, UCHRA. The UCHRA is a component of the Integra¿ CRW¿ Precision Arc Stereotactic System.
Worldwide distribution: USA (Nationwide) and countries of: Argentina, Australia, Belgium, Canada, China, Czec, Denmark, France, Hong Kong, Hungary, Italy, Japan, Malaysia, Philippines, Singapore, Spain, South Africa, and UK.
Descripción del producto
Integra CRW Precision Arc (CRWPRECISE), CRW Arc System (CRWASL), HRAIM Head Ring Assembly with Intubation Mounts || The CRW stereotactic system is used in conjunction with the HRAIM head ring is a target-centered system that can be configured to be CT-only or CTIMR compatible. The CRW stereotactic system is a multi-purpose system used for localizing intercranial targets for precisely directing instruments such as: Biopsy forceps RF lesioning electrodes Deep brain electrodes Recording and stimulating electrodes
Worldwide distribution: USA (Nationwide) and countries of: Argentina, Australia, Belgium, Canada, China, Czec, Denmark, France, Hong Kong, Hungary, Italy, Japan, Malaysia, Philippines, Singapore, Spain, South Africa, and UK.
Descripción del producto
Integra HRAIM Head Ring Assembly with Intubation Mounts || The CRW stereotactic system is used in conjunction with the HRAIM head ring is a target-centered system that can be configured to be CT-only or CT/MR compatible. The CRW stereotactic system is a multi-purpose system used for localizing intercranial targets for precisely directing instruments such as: Biopsy forceps RF lesioning electrodes Deep brain electrodes Recording and stimulating electrodes
Worldwide Distribution - USA including Illinois, Florida, Maryland, Massachusetts, North Carolina, Pennsylvania, South Dakota and Internationally to Australia, Austria, Belgium, Chile, Finland, Germany, Great Britain, Greece, Israel, Italy and Russia.
Descripción del producto
Integra Licox Test Kit REF BC10R Rx Only || An accessory provided for use with the LCXO2 and AC31 PtO2 Monitors. It provides users with a secondary means to verify the monitor's PtO2 state-of-calibration (but does not provide calibration) when needed by providing a specific electrical signal to the monitor.
The Integra Camino ICP Monitor is a compact, portable device for use with Pressure/Temperature, Pressure and Oxygen Partial Pressure Transducer-Tipped Catheters. || The CAM02 monitor measures and displays intracranial ICP) and intracranial temperature (ICT).
The Integra Licox Pt02 Monitors are compact, portable device for use with Pressure/Temperature, Pressure and Oxygen Partial Pressure Transducer-Tipped Catheters. || The LCX02 monitor measures and displays oxygen partial pressure (Pt02) and temperature in brain tissue.