Model Catalog: 50502 (Lot serial: All lots); Model Catalog: 50501 (Lot serial: All lots); Model Catalog: 2400 (Lot serial: All lots); Model Catalog: 2402 (Lot serial: All lots); Model Catalog: 2401 (Lot serial: All lots)
Descripción del producto
Cryosurgery System LM-900;Frigitronics Cryo-Plus Cryosurgery System
Model Catalog: MXKPECH00 (Lot serial: Lot # 121784); Model Catalog: MXKPEC04 (Lot serial: Lot # 117376); Model Catalog: MXKPCOND00 (Lot serial: Lot # 117443); Model Catalog: MXPCONDS05 (Lot serial: Lot # 117443); Model Catalog: MXPCONDS05 (Lot serial: Lot # 114288); Model Catalog: MXKPCOND00 (Lot serial: Lot # 114288)
Model Catalog: 88372 (Lot serial: S/N 010201 TO 050215); Model Catalog: LM-900 (Lot serial: S/N 010201 TO 050215); Model Catalog: 50501 (Lot serial: S/N 010201 TO 050215); Model Catalog: 50502 (Lot serial: S/N 010201 TO 050215); Model Catalog: 88372 (Lot serial: S/N 110101 TO 110103); Model Catalog: 88372 (Lot serial: S/N 12744 TO 13500); Model Catalog: 50501 (Lot serial: S/N 110101 TO 110103); Model Catalog: 50502 (Lot serial: S/N 110101 TO 110103); Model Catalog: 50502 (Lot serial: S/N 12744 TO 13500); Model Catalog: 50501 (Lot serial: S/N 12744 TO 13500); Model Catalog: LM-900 (Lot serial: S/N 12744 TO 13500); Model Catalog: LM-900 (Lot serial: S/N 110101 TO 110103)
Model Catalog: 2400 (Lot serial: All lots); Model Catalog: 2401 (Lot serial: All lots); Model Catalog: 2402 (Lot serial: All lots); Model Catalog: 50502 (Lot serial: All lots); Model Catalog: 50501 (Lot serial: All lots)
ClearSight(TM) 1-Day (ocufilcon D) Toric 30 daily disposable contact lenses for astigmatism --- Name and Address on Label: CooperVision Hamble, SO31 4RF, UK, and Scottsville, NY 14546 USA --- Each lens is supplied sterile in a blister containing buffered saline solution. The blister is labeled with the base curve, diameter, dioptric power, manufacturing lot number, and expiration date of the lens. ClearSight contact lenses are made from a material containing 55% water and 45% ocufilcon D, a random copolymer of 2-hydroxyethylmethacrylate and methacrylic acid. The lenses have a tint (VAT Blue 6) which is added to make the lens more visible for handling. || When placed on the cornea in its hydrated state, the ClearSight" (ocufilcon D) Soft (Hydrophilic) Contact Lens acts as a refracting medium to focus light rays on the retina.
Worldwide distribution: USA (nationwide) including states of: AZ, AR, CA, FL, GA, IN, KS, KY, LA, MD, MA, MI, MO, NJ, NY, NC, OK, PA, TN, TX, UT, and WI ; and countries of: ARGENTINA, AUSTRALIA, BELGIUM SPAIN, CANADA, CHINA, DENMARK, EMIRATES, ENGLAND, FRANCE, GERMANY, GREECE, IRELAND, MALTA, POLAND, SAUDI ARABIA, SOUTH KOREA, and TAIWAN.
Descripción del producto
DICOM Option for the Norland Illuminatus Software Revs 4.2.0 though 4.3.1. Models Norland XR-600, XR-800, XR-46, EXCELL, XR-36 and Eclipse DXA Bone Densitometers. || The XR 46 performs DXA scans of the AP Spine, Hip, Forearm, Lateral Spine, and Whole Body, as well as other user selectable sites. It provides BMD (g/cm2), Area (cm2), and BMC (g) values. It compares these values to gender and ethnic matched reference populations and provides T-Score and % young Reference, Z- Score and % age matched, and long term and short term change values. This includes sBMD (mg/cm2). The XR 46 performs soft tissue assessment and provides lean mass, fat mass, percent fat, and total soft tissue values for all scan sites, including Whole Body. The XR 46 includes a Report writer that allows the operator to customize the appearance of their report stand to automate the tedious part of the report. It also allows the user to enter ranges of patient values and the specific statements they want to be printed on their report for each of these ranges. The bone density measurements from the XR 46 can be used as an aid to physicians in determining fracture risk.
Worldwide Distribution - USA (nationwide) and Internationally to Australia, Belgium, Canada, Czech Republic, Germany, Italy, Spain, France, United Kingdom, Japan, New Zealand, South Korea, Saudi Arabia, Sweden, Singapore, Slovenia, and Taiwan.
Descripción del producto
Cooper Surgical RUMI Arch, Reusable Uterine Manipulator Handle || Ref: UMH700 || The intended use of the RUMI Arch is in an operative endoscopy (laparoscopy) where a uterus is present and where positioning of the uterus, fallopian tubes and ovaries is desirable. These types of surgeries include laparoscopic tubal ligation, and/or operative laparoscopy
Worldwide Distribution - USA (nationwide) and Internationally to Australia, Belgium, Canada, Czech Republic, Germany, Italy, Spain, France, United Kingdom, Japan, New Zealand, South Korea, Saudi Arabia, Sweden, Singapore, Slovenia, and Taiwan.
Descripción del producto
Cooper Surgical Advincula Arch , Reusable Uterine Manipulator Handle || Ref: UMH750 || The intended use of the RUMI Arch is in an operative endoscopy (laparoscopy) where a uterus is present and where positioning of the uterus, fallopian tubes and ovaries is desirable. These types of surgeries include laparoscopic tubal ligation, and/or operative laparoscopy
Worldwide Distribution: US (nationwide) and internationally to: Canada, Latin America, EU, Asia Pacific, and Africa/Central Eurasia countries.
Descripción del producto
ProClear Toric contact lenses are made from a material containing 62% water and 38% omafilcon B, a random copolymer of 2-hydroxyethylmethacrylate and methacrylic acid. The lenses have a tint (VAT Blue 6) which is added to make the lens more visible for handling.