Integrated Orbital Implants Inc

3 dispositivos en la base de datos

  • Modelo / Serial
    Lot/Unit Codes: 32764, 35906, 35907, 35908, 36307, 36308, 36309, 36315, 36316, 36364, 36430, 36431, 36469, 36470, 36471, 36476, 49216, 54304, 54569, 63449, 63450, 63710, 63803.
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    Yes
  • Distribución
    Worldwide Distribution - USA (nationwide) and the countries of nationwide and worldwide to: Japan, Greece, Germany, Romania, UAE, Australia, Canada, Philippines, Korea, Taiwan, Chile, Denmark, UK, Italy, Pakistan, Turkey, Philippines, India, South Africa, and Singapore.
  • Descripción del producto
    Product Brand Name: Coated Bio-Eye Orbital Implant w/Conformer. || Product Generic Name: Implant, Eye Sphere Wrap, Implant, Orbital. || Model Number: I0016C, I0018C, I0020C, I0022C, I0024C. || Description of the product: The Coated Bio-Eye consists of a coralline hydroxyapatite sphere encased in a resorbable shell that aids in || implant insertion and provides a means of securing muscles to the implant. || The Coated Bio-Eye Orbital Implant is indicated in orbital implantation following enucleation, or as a secondary orbital implant following extrusion, migration or rotation of primary orbital implants. It is indicated in any situation where materials such as silicone, acrylic, polyethylene or glass orbital implants would be used.
  • Modelo / Serial
    Lot number: M-50021 Product is not serialized.  Note: Lot code assigned by the contract manufacturing firm.
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    Yes
  • Distribución
    Worldwide, including USA, United Arab Emirates, Canada, Mexico, Costa Rica, Taiwan & Romania.
  • Descripción del producto
    Perry-Kolberg Titanium Motility/Support System (Threaded Sleeve and Flat Peg), Model Number 100045 || The threaded sleeve and flat peg are two components of the P-K Titanium Motility/Support System. The threaded sleeve is an externally threaded cylinder and an internal drilled hole designed to receive a peg. It is placed in the Bioeye Hydroxyapatite Implant with the use of the P-K Titanium threaded sleeve wrench after a hole has been prepared in the implant by drilling with a series of hypodermic needles of gradually increasing sizes. After the threaded sleeve is placed in the implant, any of the P-K Pegs can be inserted. || The affected model which is the subject of this recall comes with the flat peg.
  • Modelo / Serial
    Lot/Unit Codes: 976115CC, Serial Numbers: 2000509, 207025, 207557, 44993, 62774, 205928, 201933, 203550, 205927, 202939
  • Clasificación del producto
  • Clase de dispositivo
    2
  • ¿Implante?
    Yes
  • Distribución
    Internationally to Finland & France
  • Descripción del producto
    Bio-Eye Hydroxyapatite (HA) Orbital Implant and Conformer, Model Number: 100020S

2 fabricantes con un nombre similar

Más información acerca de la data acá

  • Dirección del fabricante
    SAN DIEGO
  • Source
    HC
  • Dirección del fabricante
    Integrated Orbital Implants Inc, 12625 High Bluff Dr Ste 300, San Diego CA 92130-2054
  • Empresa matriz del fabricante (2017)
  • Source